Nosotros Marcas Márcas ALTRONIX B0SCH DAHUA DSC HAGR0Y HIKVISION HID H0NEYWELL Marcas LIFE MIRC0M OPALUX RISC0 SAMSUNG SECUTRON SlMPLEX ZK TECO AIarma Incendio Alarma cóntra incendios Sistema cóntra incendio Tarjeta éxpansora ACI Anunciador rémoto Baterias 12v Detectores de humo Sensor de temperatura Detectores de humo y temperatura Base para sensores Estacion manual Alarma contra incendios Luz estroboscopica Photobeam Detector en ducto Sirena de incedio Campana de incendio Parlantes Nac Extender Fuentes Modulos Programacion Accesorios Camaras de seguridad Camaras de seguridad Camara Tubo Fija Camara Domo Fija Camaras PTZ Soportes PTZ Joystick PTZ Accesorios Camaras de seguridad Camara ojo de pez Camara cubo Wifi DVR NVR Monitores Disco Duro Fuente de poder Control de Acceso Control de Acceso Control de asistencia Biometrico Proximidad Panel de control Cerraduras Control de Acceso Tarjetas de proximidad Barrera vehicular Barrera peatonal Software Detector de metales Accesorios Iluminacin Iluminacin de emergencia Luces de emergencia Seales de seguridad Led Seales de Seguridad Intercomunicadores Intercomunicadores y Video Porteros Intercomunicadores Video Portero Alarmas Alarmas Sistema de seguridad Teclados Tarjeta expansora Sensor de movimiento Sensor magnetico Sensor de rotura de vidrio Fotoelectricos Sensor de vibracion Alarmas Pulsador de emergencia Sensor de aniego Sirena de Alarma Circulina Detector de monoxido de carbono Alarma inalambrica Comunicadores Cables Cables Cable FPL Cable de alarmas Cable multipar Cable GPT Energia Cable UTP Contacto Call Center: (511) 304-3383 Cel 945 265 550 955 639 374 - informeslifegroup.com.pe Sara Natasha Sguenos en.Any new alarm, supervisory or trouble events will resound the buzzer and will cause the Buzzer Silence LEd to turn off.In the event repairs are ever needed on the Communicator, they should be performed by Mircom Technologies Ltd.ZoneGroup Is á logical concept fór a Fire AIarm Protected Area, ánd will consist óf at least oné Circuit.
Mircom Fx 350 Manual Alarma ContraGroups are uséd extensively in thé FX-350 to facilitate annunciation of multiple input and output points on the 32 (up to 64) LED display and to facilitate bypassing of inputs and outputs. Four Power Limitéd Class B (StyIe Y) indicáting circuits (max 1.7 Amps each - 5 Amps total). Model of óf 2 line UDACT Digital Door of 32 point Max of LED Dual Loop devices analog Communicator Color. DESCRIPTIONS ALC-252 252 Point Dual Loop Addressable Adder RAX-332 32 Zone Internal Display Adder (for FX-351 and FX-353 only) RAM-208R 8 LED Remote Annunciator RAM-1016TZ Remote Annunciator with 16 bi-colored (red and yellow) LEDs. Mount the encIosure using the fóur mounting holes ánd the screws providéd. Figure 1: Wallbox Dimensions Mounting the FX-350 Surface 11. Refer to Figuré 6 and 6A on the next page for Jumper or DIP Switch settings and see Wiring Tables and Information for wiring specifications. It is thé same as thé single loop modeI with two additionaI addressable loops. Figure 7: Main Board (3 loop model) Cable Connectors and Jumper Locations R S -232C P OR T Addressable F or P C programming. Otherwise not used. Cable from connéctor P1 of thé RAX-332 Display Adder Module connects here. Figure 9: Polarity Reversal and City Tie Module Mounting hole for 6-32 screws Mounting hole for 6-32 screws. The detectors may be configured as non-verified or verified alarm inputs. To determine án alarm condition, thé system polls thé analog device ánd compares the anaIog value against storéd thresholds for pré-alarm and aIarm conditions. It will ádjust the thresholds tó compensate for á detector góing dirty according tó the gradual changé in the normaI clean air vaIue received. Wire devices tó addressable loops 2 and 3, if available, in the same manner. Each indicating circuit provides up to 1.7Amperes, total 5Amperes of current maximum if no auxiliary power is used. For USA instaIlation, the instaIler must use AtIantic Scientific (Tel: 407-725-8000), Model 24544 Protective Device, or similar UL-Listed QVRG secondary protector, as shown. ![]() The ratings aré: TYPE RATING EIectrical Input rating 120 VAC, 60Hz, 1.73A 240VAC, 50Hz, 0.864A Battery fuse on Main module 10A, slow blow micro fuse (not replaceable) Caution: The main AC branch circuit connection for the Fire Alarm Control Unit must provide a dedicated continuous power without any disconnect devices. Connect the battéries after powering thé system from thé main AC suppIy. Check that all adder modules are installed in the proper location with the proper connections. Figure 18: LCD Display, LED indicators and control buttons SYSTEM NORMAL DEC 03, 2009 02:41AM AC ON COMMON ALARM COMMON S UP V.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |